Lithium cell licences need rated capacity test reports from May 2027
From May 1, 2027, renewals, inclusions and new registrations for lithium cells and batteries under IS 16046 (Part 2) need a rated capacity test report. The Bureau of Indian Standards issued it on November 11, 2026. It applies to portable sealed secondary lithium cells and batteries under IS 16046 (Part 2):2018/IEC 62133-2:2017. It applies with immediate effect.
The Bureau of Indian Standards (BIS), Registration Department, issued guidelines under reference IS 16046 (Part 2), dated November 11, 2026, for verifying the rated capacity of portable sealed secondary lithium cells and batteries. Cells and batteries certified to IS 16046 (Part 2):2018/IEC 62133-2:2017 must also be tested for rated capacity under clause 7.3.1 of IS 16047 (Part 3):2018/IEC 61960-3:2017 ("Discharge performance at 20 deg C [rated capacity]"). The guidelines supersede the earlier implementation guidelines, REF: IS 16046 (Part 2), dated February 10, 2026, and come into force with immediate effect. They are signed by Ankita Dhule, Sc C.
IS 16046 (Part 2) is notified by MeitY under the Electronics and IT Goods (Requirements for Compulsory Registration) Order, 2021. The guidelines put into effect MeitY's office memorandum W-47/14/2024-IPHW, dated February 3, 2026, which says that "rated capacity for sealed secondary Lithium cells and batteries shall be measured in accordance with the test method for rated capacity specified in clause 7.3.1 of IS 16047: part3, and shall be reported for compliance under IS 16046(Part 2)".
For existing licensees, licences stay valid until the end of their validity period, but samples picked up during surveillance must meet the rated capacity limits. The requirement applies to renewals, inclusions and new registrations from May 1, 2027, so a licence whose validity ends on or after that date needs the rated capacity test report at renewal. Licensees must file third-party laboratory test reports for all lead models in the existing scope: they raise a test request through LIMS for IS 16046 (Part 2) and apply online through the Standard Revision/Amendment/Essential Requirement Module. The laboratory gives the number of the safety test report the models were tested under, and reports the measured capacity under Clause 4 of the modified Unified Test Report Format. Licensees also give an undertaking that their remaining models comply.
A licensee that hasn't completed these steps by the applicable dates may face suspension or cancellation of the licence, or deletion of a model from the licence's scope. The guidelines don't state the rated capacity limits themselves.
For new applicants, an application whose sample is already at the laboratory, or whose test report is already issued, may be processed without the extra test. Other applications already in process go ahead if the applicant undertakes to submit the clause 7.3.1 report by the last date of the licence's validity. After April 30, 2027, BIS will grant no licence under IS 16046 (Part 2) unless the test report includes rated capacity. The same rules apply to a change in scope or inclusion, with the requirement starting May 1, 2027.
- Issued by
- Bureau of Indian Standards, Registration Department
- Document
- Guidelines for verification of rated capacity [Clause 7.3.1 of IS 16047 (Part 3):2018/IEC 61960-3:2017] for portable sealed secondary lithium cells and batteries; Ref: IS 16046 (Part 2)
- Dated
- November 11, 2026
- Applies to
- Portable sealed secondary lithium cells and batteries under IS 16046 (Part 2):2018/IEC 62133-2:2017
- Test
- Clause 7.3.1 of IS 16047 (Part 3):2018/IEC 61960-3:2017, discharge performance at 20 deg C (rated capacity)
- Basis
- MeitY OM W-47/14/2024-IPHW, February 3, 2026; Electronics and IT Goods (Requirements for Compulsory Registration) Order, 2021
- Existing licences
- Valid to the end of their validity; surveillance samples must meet rated capacity limits
- Renewals, inclusions and new registrations
- Rated capacity test report required from May 1, 2027
- What licensees file
- Third-party laboratory reports for all lead models in scope, and an undertaking for the remaining models
- Last grant without the test
- No licence under IS 16046 (Part 2) after April 30, 2027 without rated capacity in the test report
- If not done
- Suspension or cancellation of the licence, or deletion of a model from scope, may be initiated
- Takes effect
- With immediate effect
- Replaces
- Implementation guidelines REF: IS 16046 (Part 2), February 10, 2026
- Signed by
- Ankita Dhule, Sc C
The guidelines (PDF, 139 KB)
Source: BIS's own copy.
Checked against the official copy on November 12, 2026.