Type approval of diagnostic X-ray machines: BIS certification mark and AERB safety testing

The Atomic Energy Regulatory Board (Radiological Protection Division) issued the Type Approval of Diagnostic X-ray Machines. Each make and model of diagnostic X-ray unit needs the BIS certification mark under IS 7620 and AERB radiation safety testing before type approval.

Type Approval of Diagnostic X-ray Machines · Atomic Energy Regulatory Board (Radiological Protection Division)

IndusDesk ·

This record is a letter of the Atomic Energy Regulatory Board, Radiological Protection Division, dated October 10, 1994, addressed to manufacturers of diagnostic X-ray machines in the country, on the subject of type approval of diagnostic X-ray machines.

The letter states that each make and model of X-ray unit must bear the certification mark of the Bureau of Indian Standards, granted on demonstration of conformance with IS 7620, and that equipment bearing the mark will be further tested by the Board for compliance with radiation safety requirements. Equipment without the BIS certification will not be considered for type approval, and equipment without type approval is not to be supplied to users or used for radiological examination of humans.

Manufacturers must give the user a certificate of the quality assurance tests carried out after installation at the user's premises, repeat the tests whenever the equipment is serviced or repaired, and protect their workers against radiation exposure, entrusting that responsibility to a qualified and trained person approved by the competent authority under the Radiation Protection Rules, 1971. Formats for the type approval application, the quality assurance test report and the approval of a radiological safety officer are attached. Manufacturers were asked to comply at the earliest, and not later than a date in 1995.

Order
Type Approval of Diagnostic X-ray Machines
Issued by
Atomic Energy Regulatory Board (Radiological Protection Division)
Product group
Medical Equipment
Where it stands
In force
What it requires
Each make and model of diagnostic X-ray unit manufactured in the country must bear the certification mark of the Bureau of Indian Standards, granted on demonstration of conformance with IS 7620, and is then tested by the Atomic Energy Regulatory Board for compliance with radiation safety requirements. Equipment without the BIS certification will not be considered for type approval, and equipment without type approval must not be supplied to users or used for radiological examination of humans.
Enforcement
Type approval is granted by the Competent Authority; the Atomic Energy Regulatory Board tests equipment bearing the BIS certification mark for compliance with radiation safety requirements.

The products and their standards

ProductIndian Standard
Diagnostic X-ray machines (each make and model of X-ray unit)IS 7620 (Part 1)

Every notification on this order

DateNotificationStatusWhat it did
January 31, 2001AERB/443/39 MDX/3509/94 PDF, 1.1 MBIn forceA letter of the Atomic Energy Regulatory Board, Radiological Protection Division, dated October 10, 1994, on type approval of diagnostic X-ray machines, requiring the BIS certification mark and AERB radiation safety testing before type approval, quality assurance test certificates after installation and after each service or repair, and radiation protection of workers.

Each notification is linked, as a PDF, in the list above.